Scientists from the Grossman School of Medicine at New York University conducted a pilot study with 10 outpatient participants with schizophrenia or schizoaffective disorder. The average age of the participants was 37.5 years, with equal numbers of men and women. The work was published in the journal npj Acoustics.

Schizophrenia and related conditions are chronic mental illnesses in which a person perceives reality in a distorted way. Two key symptoms are hallucinations (for example, voices that are not there) and delusions, that is, persistent beliefs that do not yield to argument. Medications help many, but some patients continue to suffer from delusions even while on treatment.

The researchers directed low-intensity focused ultrasound at the right internal globus pallidus, a paired structure deep in the brain that is involved in filtering signals and assessing the significance of events. The method does not require surgery: a curved device is applied to the head, and sound waves are focused in a narrow zone deep inside, temporarily changing the excitability of nerve cells without heating tissue.

In the trial, each participant underwent two sessions a week apart: real stimulation and a sham (placebo), with the order determined randomly. Neither the patients nor the doctors assessing them knew which was which. The active session lasted 10 minutes: short pulses of 30 seconds with equal pauses. Symptoms were assessed six times: before, during, immediately after, an hour later, a day later and a week later.

After active stimulation, delusion scores on average decreased by 1.2, while after the sham they rose by 0.4 (baseline about 12-16 points). Adjusted for time and session order, the advantage of ultrasound was 1.56 points, a moderate effect size (Cohen's d = 0.68). This is a statistical quantity showing the strength of the difference between groups. Auditory hallucinations did not change significantly. There were no serious adverse events; seven people reported mild short-term symptoms after the active session, and all ten after the sham.

Interestingly, the effect did not disappear immediately: the difference between the active and sham sessions reached 1.90 points after a day and 2.70 points after a week. However, these point comparisons were not statistically significant after correction for multiple testing. The authors suggest that ultrasound may trigger gradual changes in glutamate signaling, but they emphasize that the study was not designed to confirm such effects.

The lead author, Wei Qi, noted: "This is an encouraging first step, but not yet a treatment." According to him, the method does not replace medication: all participants continued their usual therapy. The scientists plan a larger trial with repeated sessions and long-term follow-up. The limitations of the pilot work: only 10 people, one session, the inability to analyze fMRI due to technical problems, and insufficiently complete verification of blinding. In addition, the correlation between stimulation and reduction in delusions does not by itself prove a causal relationship.

Source: PsyPost